Αρχική Σελίδα
Προϊόντα
Σχετικά με εμάς
Γύρος εργοστασίων
Ποιοτικός έλεγχος
Επικοινωνήστε μαζί μας
Συνομιλία τώρα
Νέα
ιστολόγιο
Αρχική Σελίδα ΠροϊόνταHot Water Meter

Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter

Είμαι Online Chat Now
Συνομιλία τώρα

Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter

Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter
Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter

Μεγάλες Εικόνας :  Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter

Λεπτομέρειες:
Τόπος καταγωγής: Κίνα
Μάρκα: HUIYUE
Αριθμό μοντέλου: Z-RLM (C)-DN50-500
Πληρωμής & Αποστολής Όροι:
Ποσότητα παραγγελίας min: 100
Τιμή: 20~150
Χρόνος παράδοσης: 2~3 εβδομάδες
Όροι πληρωμής: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Δυνατότητα προσφοράς: 100
Λεπτομερής Περιγραφή Προϊόντος
Εγγύηση: 1 έτος, 1 έτος Προσαρμοσμένη υποστήριξη: OEM, ODM
Πιέζοντας: 1,6 MPa Τύπος: ΥΔΡΟΜΕΤΡΗΤΗΣ WOLTMANN
Τύπος μέτρησης: Μέτρηση Θερμικής Ενέργειας CommunicationInterface: M-Bus / Ασύρματο
Όνομα τύπου: Οριζόντιος Υγρός μετρητής ζεστού νερού DisplayType: Ψηφιακή οθόνη
Κατηγορία προστασίας: IP65 Θερμοκρασία νερού: ≤90℃
Υλικό: Σώμα ορείχαλκου Πίεση εργασίας: ≤1MPa
Φουλάντζερ: 0,6 έως 6 m³/h Ιδιοσυγκρασία: 5°C σε 90°C
Κανονικό μέγεθος: 80mm~200mm
Επισημαίνω:

Large Bore Ultrasonic Heat Meter

,

Hard water ultrasonic heat meter

,

maintenance friendly ultrasonic heat meter

Large-diameter ultrasonic heat meter with dual cold and hot metering, low power consumption, high precision, MBus/RS485/GPRS interface, and is the mainstream meter for heating pipelines and air conditioning systems. It has a wide range of uses.

 

Applicable:

heat metering at the entrance of buildings and areas for centralized heating and cold/heat energy metering for central air conditioning systems. It can be combined with a temperature controller remote control valve, data collector, concentrator, and management software to build a "Heat Metering Management System Based on On-Off Time Area Method" and a "He Metering Management System Based on Temperature Area Method" to achieve smart heating and remote management.

Product Application:

It is used to measure the actual heat energy consumption urban heating main pipelines, building heating main pipelines, and the cold and heat energy consumption of the main pipeline of the central air conditioning system, etc.

Applicable Standards CJ128-2007 "Heat Meter" Industry Standard, GB/T 32224-2015 "at Meter" National Standard, JJG225-2001 "Thermal Energy Meter" Inspection Procedure;

Product Features:

1. Small starting flow, combined with unique patented technology, ensures the accuracy and stability of flow measurement;

2. Can be installed horizontally or vertically;

3. High, meeting EN1434 and CJ 128 metrological performance requirements;

4. Automatic error diagnosis and alarm function

5. Low power consumption technology is, and the battery life is long;

6. The structure has no moving parts and is not affected by impurities in the medium, never wearing out;

7. Direct- meter body structure, ensuring stable flow field morphology and low pressure loss;

8. Dual cold and hot metering functions, intelligent calculation of energy consumption;

9. 1-month data storage and query function;

10. Data protection and data recovery function in case of power failure;

11. Not affected by external magnetic field interference, performance;

12. Automatic prompt when battery power is low;

13. The integrating meter has a separate structure, which is convenient for observation and reading; 1. M-bus or RS485 communication interface is provided, which can realize data transmission and centralized control;

 

Technical Parameters:

 

Nominal bore; Usual flow rate Flow range; Maximum working pressure Temperature range Temperature difference range Length Width Height Connected flange
(mm) (m³/h) (m³/h) (Mpa) (℃) (k) (mm) (mm) (mm) link bolt Bolt hole center circle diameter
50 15 0.6~30 1.0 4~95 3~70 200 170 185 4-M16 125
65 25 1~50 1.0 4~95 3~70 200 185 200 4-M16 145
80 40 1.6~80 1.0 4~95 3~70 225 250 220 8-M16 160
100 60 2.4~120 1.0 4~95 3~70 250 270 250 8-M16 180
125 100 4~200 1.0 4~95 3~70 250 300 270 8-M16 210
150 150 6~300 1.0 4~95 3~70 300 330 320 8-M20 240
200 250 10~500 1.6 4~95 3~70 350 380 360 8-M20 295
250 400 16~800 1.6 4~95 3~70 450 450 420 12-M22 355
300 600 24~1200 1.6 4~95 3~70 500 500 480 12-M22 410
350 750 30~1500 1.6 4~95 3~70 500 560 540 16-M22 470
400 1000 40~2000 1.6 4~95 3~70 500 610 600 16-M27 525
450 1200 48~2400 1.6 4~95 3~70 500 670 650 20-M27 585
500 1500 60~3000 1.6 4~95 3~70 500 720 720 20-M30 650
 

Στοιχεία επικοινωνίας
Zhuhai Huiyue Technology Co., Ltd

Υπεύθυνος Επικοινωνίας: HUANG

Τηλ.:: 13750007780

Στείλετε το ερώτημά σας απευθείας σε εμάς (0 / 3000)