منزل
المنتجات
حول بنا
جولة في المعمل
ضبط الجودة
اتصل بنا
نتحدث الآن
أخبار
مدونات
منزل المنتجاتHot Water Meter

Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter

ابن دردش الآن
نتحدث الآن

Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter

Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter
Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter

صورة كبيرة :  Large bore ultrasonic heat meter;maintenance friendly heat meter, calorimeter for hard water, long life heat meter

تفاصيل المنتج:
مكان المنشأ: الصين
اسم العلامة التجارية: HUIYUE
رقم الموديل: Z-RLM(C)-DN50-500
شروط الدفع والشحن:
الحد الأدنى لكمية: 100
الأسعار: 20~150
وقت التسليم: 2 ~ 3 أسابيع
شروط الدفع: خطاب الاعتماد، D/A، D/P، T/T، ويسترن يونيون، موني جرام
القدرة على العرض: 100
مفصلة وصف المنتج
ضمان: سنة واحدة ، سنة واحدة دعم مخصص: تصنيع المعدات الأصلية، أوديإم
تصنيف الضغط: 1.6 ميجا باسكال يكتب: عداد المياه فولتمان
نوع القياس: قياس الطاقة الحرارية واجهة الاتصالات: إم باص / لاسلكي
اكتب الاسم: عداد الماء الساخن من النوع الرطب الأفقي نوع العرض: LCD الرقمية
فئة الحماية: IP65 درجة حرارة الماء: ≤90 ℃
مادة: جسم نحاسي ضغط العمل: ≤1MPA
Flowrange: 0.6 إلى 6 م³/ساعة درجة الحرارة: 5 درجة مئوية إلى 90 درجة مئوية
الحجم الطبيعي: 80 مم ~ 200 مم
إبراز:

Large Bore Ultrasonic Heat Meter,Hard water ultrasonic heat meter,maintenance friendly ultrasonic heat meter

,

Hard water ultrasonic heat meter

,

maintenance friendly ultrasonic heat meter

Large-diameter ultrasonic heat meter with dual cold and hot metering, low power consumption, high precision, MBus/RS485/GPRS interface, and is the mainstream meter for heating pipelines and air conditioning systems. It has a wide range of uses.

 

Applicable:

heat metering at the entrance of buildings and areas for centralized heating and cold/heat energy metering for central air conditioning systems. It can be combined with a temperature controller remote control valve, data collector, concentrator, and management software to build a "Heat Metering Management System Based on On-Off Time Area Method" and a "He Metering Management System Based on Temperature Area Method" to achieve smart heating and remote management.

Product Application:

It is used to measure the actual heat energy consumption urban heating main pipelines, building heating main pipelines, and the cold and heat energy consumption of the main pipeline of the central air conditioning system, etc.

Applicable Standards CJ128-2007 "Heat Meter" Industry Standard, GB/T 32224-2015 "at Meter" National Standard, JJG225-2001 "Thermal Energy Meter" Inspection Procedure;

Product Features:

1. Small starting flow, combined with unique patented technology, ensures the accuracy and stability of flow measurement;

2. Can be installed horizontally or vertically;

3. High, meeting EN1434 and CJ 128 metrological performance requirements;

4. Automatic error diagnosis and alarm function

5. Low power consumption technology is, and the battery life is long;

6. The structure has no moving parts and is not affected by impurities in the medium, never wearing out;

7. Direct- meter body structure, ensuring stable flow field morphology and low pressure loss;

8. Dual cold and hot metering functions, intelligent calculation of energy consumption;

9. 1-month data storage and query function;

10. Data protection and data recovery function in case of power failure;

11. Not affected by external magnetic field interference, performance;

12. Automatic prompt when battery power is low;

13. The integrating meter has a separate structure, which is convenient for observation and reading; 1. M-bus or RS485 communication interface is provided, which can realize data transmission and centralized control;

 

Technical Parameters:

 

Nominal bore; Usual flow rate Flow range; Maximum working pressure Temperature range Temperature difference range Length Width Height Connected flange
(mm) (m³/h) (m³/h) (Mpa) (℃) (k) (mm) (mm) (mm) link bolt Bolt hole center circle diameter
50 15 0.6~30 1.0 4~95 3~70 200 170 185 4-M16 125
65 25 1~50 1.0 4~95 3~70 200 185 200 4-M16 145
80 40 1.6~80 1.0 4~95 3~70 225 250 220 8-M16 160
100 60 2.4~120 1.0 4~95 3~70 250 270 250 8-M16 180
125 100 4~200 1.0 4~95 3~70 250 300 270 8-M16 210
150 150 6~300 1.0 4~95 3~70 300 330 320 8-M20 240
200 250 10~500 1.6 4~95 3~70 350 380 360 8-M20 295
250 400 16~800 1.6 4~95 3~70 450 450 420 12-M22 355
300 600 24~1200 1.6 4~95 3~70 500 500 480 12-M22 410
350 750 30~1500 1.6 4~95 3~70 500 560 540 16-M22 470
400 1000 40~2000 1.6 4~95 3~70 500 610 600 16-M27 525
450 1200 48~2400 1.6 4~95 3~70 500 670 650 20-M27 585
500 1500 60~3000 1.6 4~95 3~70 500 720 720 20-M30 650
 